Description / Abstract:
Material Description. This specification covers
the requirements for a closed cell, foam-in-place thermoplastic
material to be used as a seal against air, dust, and water. The
material may also be used for certain applications as a gasket or
rattle isolator. Materials meeting the requirements of this
specification will be comprised of two (2) classes and several
types.
- Class l: Materials will be used for air, dust and rattle
isolators.
- Class II: Materials will be used for water sealing and must
meet the water impermeability requirements of this document.
Materials are divided into types, depending on
chemistry.
- Type I: Thermoplastic Rubber Based Material.
- Type II: Thermoplastic Urethane Based Material.
- Type III: Other technology to be called out on
drawing.
Symbols. Not applicable.
Applicability. Materials to be used as air and
dust seals or water seals and gaskets in the body area and for
rattle protection and other suitable applications.
Remarks.
The material must not stain, attack, or have any other
objectionable effect on adjacent surfaces.
This material is foamed through the introduction of an inert
gas, such as nitrogen, carbon dioxide, or compressed air to a
specific density reduction. The material is allowed to cool with
the gas bubbles intact and a closed cell foam product is formed.
Density reduction denotes the percentage of inert gas content. The
amount of density reduction/gas content must be specified on the
drawing.